     TBG_1600_ME

   
Üretici : BALTUR
Ürün Özellikleri
Brülörler şunlardan oluşur: EN 676 Avrupa Standartları ve 2006/42/CE; 2006/95/CE; 97/23/CE; 2004/108/CE sayılı Avrupa Yönergelerine uygun gaz brülörü.
        Detaylar
 
 
Detaylar

Gas burner compliant with European standard EN676. Electronic operation at two progressive stages.

Continuous modulation operation by installing P.I.D. controller in the control panel (to be ordered separately with modulation probe).

Modulation ratio 1:10.

Gas burner with low NOx and CO emissions in accordance with European standard EN676: class 2.

Combustion air intake with throttle damper. Air flow adjustment with electric servomotor.

Fully closing air damper on shutdown to avoid loss of heat through the chimney.

Maintenance facilitated by the possibility of removing the combustion head without having to remove the burner from the boiler.

Fixed boiler coupling flange.

Easy maintenance thanks to the twosides

hinge which allows the removal of the combustion head without having to remove the burner

from the boiler.

CE version main gas train is complete with operation and safety valve with electromagnetic drive, valve tightness control, minimum and

maximum pressure switch, pressure regulator and gas filter

Fail proof connectors for burner/gas train connection

Gas train exit: high/low.

Flame detection by ionisation electrode with connector for micro amp meter.

Control panel equipped either with display showing the working process and with the keyboard for the burner adjustment.

Terminal board for the electric and thermostatic connections to the burner.

Terminal board for second stage operation or for the connection of the PID electronic regulator.

Electrical system with protection rating IP54.






TEKNIK ÖZELLIKLER

MODEL TBG 1600 ME

MAKSİMUM TERMİK GÜÇ - METAN kW 16000

MİNİMUM TERMİK GÜÇ - METAN kW 1600

METAN EMİSYONLARI mg/kWs Classe II (≤ 120 mg/kWh)

İŞLEYİŞ İki kademeli ilerlemeli modülasyonlu

METAN TRANSFORMATÖR 50 Hz 8 kV 30 mA 230 V

MAKSİMUM TERMİK KAPASİTE - METAN Stm³/h 1690

MİNİMUM TERMİK KAPASİTE - METAN Stm³/h 169

MAKSİMUM BASINÇ - METAN mbar 500

MİNİMUM METAN BASINCI mbar 125

FAN MOTORU 50Hz kW 30

EMİLEN ELEKTRİK GÜCÜ* 50Hz kW 31

BESLEME GERİLİMİ 50 Hz 3N~ 400V ± %10

KORUMA DERECESİIP54

ALEV ALGILAMASI İONİASYON SONDASI

CİAZ BT 320

SES BASINCI** dBA 94.4

SES GÜCÜ*** dBA 103.8

AMBALAJLI AĞIRLIK kg 704

AMBALAJSIZ AĞIRLIK kg 490

KULLANILACAK MALZEMELER

İZOLASYON CONTASI 2

KELEPÇELER 8 adet M20

ALTIGEN SOMUNLAR 8 adet M20

DÜZ RONDELA 8 adet Ø20

NİPEL

Referans koşullarda alt yanma değeri 15° C, 1013 mbar:

Metan gazı Hi = 9,45 kWh/Stm³= 34,02 Mj/Stm³* Hareket fazıda, ateşeme transformatöüdevrede iken, toplam emiş

Öçüler, EN 15036 - 1 sayıınorma uygun olarak Baltur laboratuvarıda gerçkleşirilmişir.

** Maksimum nominal termal kapasitede çlışn brüölücihazı bir metre arkasıda, Baltur laboratuvar ortamıkoşllarıda öçüen

ve farklıbögelerde yapıan öçülerle karşıaşııamayan ses basıcı

*** Ses güü önek bir ses kaynağıile Baltur laboratuvarıda elde edilmişir; bu öçü,1.5 dB (A) değrinde standart bir sapma ile

kategori 2 (müendislik sııı hassasiyetine sahiptir.

 
 